Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Military Medical Sciences ; (12): 906-911, 2017.
Article in Chinese | WPRIM | ID: wpr-694279

ABSTRACT

Objective To make portable the detector for up-converting phosphor (UCP) immune lateral flow assay portable and increase the test precision by developing an area CCD-based detection system for UCP immune lateral flow assay.Methods The excitation light source was a 980 nm and 300 mW laser diode.In order to decrease the error induced by the un-uniformity of laser irradiation,a uniformity mirror was inserted in the beam and a calibration algorithm was optimized.The residual error from the un-uniformity irradiation was less than 1%.Results Thanks to the adjustability of the exposure time,the dynamic range of detection of the system was as high as 106 dB.The repeat test error for the very low signal was 1% (variation coefficient).The linear correlation coefficient between the tested T/C value and sample concentration was 0.998.Conclusion Compared to is traditional instrument,this detection system is static,portable and highly precise.

2.
Chinese Journal of Pediatrics ; (12): 858-861, 2011.
Article in Chinese | WPRIM | ID: wpr-356359

ABSTRACT

<p><b>OBJECTIVE</b>To explore the clinical effect of low dose pituitrin in children with septic shock.</p><p><b>METHODS</b>A total of 48 pediatric cases with septic shock, in whom 6 hours, conventional treatment could not reverse shock from January 2008 to December 2010, were selected for this study. The patients were divided into two groups randomly (completely random design) (control group 24, remedial group 24). The conventional treatment included antibiotics/fluid resuscitation/correcting acid-base imbalance, glucocorticoid, organ (heart/lung) support, dopamine 1 - 15 µg/(kg·min) and norepinephrine 0.5 - 2 µg/(kg·min) pumped in continuously in the control group. In initial 6 hours the same treatment was given to the remedial group, while low dose pituitrin (0.01 - 0.03 U/min) was pumped additionally during the rest of time. The therapeutic effect on correcting shock was evaluated in both groups.</p><p><b>RESULTS</b>The total effective rate was 76.2% in the remedial group and 40.0% in the control group; the mortality was 33.3% and 60% respectively. The difference between both groups was significant (P = 0.025).</p><p><b>CONCLUSION</b>Low dose pituitrin could improve the clinical effect significantly in children with septic shock in whom 6 hours conventional treatment failed to correct shock, shorten the total periods of treatment, and decrease mortality.</p>


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Norepinephrine , Therapeutic Uses , Pituitary Hormones, Posterior , Therapeutic Uses , Shock, Septic , Drug Therapy , Treatment Outcome , Vasoconstrictor Agents , Therapeutic Uses
SELECTION OF CITATIONS
SEARCH DETAIL